I-VU® WSHP WATER-TO-WATER OPEN CONTROLLER OPN-WSHPW2WM
Application Features
- Controls up to 4 stages of capacity (up to 3 compressor stages), to maintain the desired entering or leaving water temperature
- Provides 5 operating modes for manual or automatic system changeover operation
- Provides load water pump output control
- Provides source water pump or 2-position isolation valve control
- May be configured to reset the water temperature proportionally based upon OAT during cooling or heating modes
- In cooling mode, the control has the capability to limit the OAT reset based upon the difference between a measured humidity value and a configured high RH setpoint limit
- For larger installations, a total of up to 8 stages may be controlled as a singular heating or cooling source. One controller will operate as the master, coordinating others in the system
Hardware Features
- Compatible with Aquazone™ water-to-water water source heat pumps with Puron® refrigerant
- Integrates easily into any BAS using BACnet, Modbus, LonWorks or N2 protocols
- On-board hardware clock, remote occupancy input, and support for communicating/thermistor sensors provide stand-alone operation
- Easy startup and commissioning using i-Vu User Interfaces
System Benefits
- Integrated Carrier Condenser Water Linkage algorithm for plug-and-play integration with the source water system when controlled by a Carrier water loop controller
- Fully plug-and-play with the Carrier i-Vu Building Automation System
- Supports demand limiting for maximum energy savings
WSHP WATER-TO-WATER OPEN
Product Integrated Water Source Heat Pump Control
Carrier’s Water-to-Water (W2W) Open controller is an integrated component of a Carrier water-to-water source heat pump. The W2W Open controller continuously monitors and regulates heat pump operation with reliability and precision. This advanced controller features a sophisticated, factory-engineered control program that provides optimum performance and energy efficiency. For added flexibility, the W2W Open controller is capable of stand-alone operation. It can also be integrated with any Building Automation System using the BACnet®, Modbus®, LonWorks®*, or N2 protocol.
*Requires LON Option Card (p/n LON-OC)
Offering I-VU® WSHP WATER-TO-WATER OPEN CONTROLLER OPN-WSHPW2WM in:
VIRGINIA: Alexandria, Annandale, Arlington, Ashburn, Burke, Centreville, Chantilly, Crystal City, Dale City, Dulles, Fairfax, Falls Church, Fort Belvoir, Great Falls, Herndon, Leesburg, Lincoln, Lorton, Manassas, McLean, Oakton, Purcellville, Reston, Springfield, Stafford, Sterling, Vienna, Woodbridge.
MARYLAND: Annapolis, Aspen Hill, Beltsville, Bethesda, Chevy Chase, College Park, Gaithersburg, Hampstead, Hyattsville, Lanham, Laurel, Montgomery Village, Potomac, Rockville, Silver Spring, Takoma Park, Temple Hills, National Harbor, Cabin John, East Riverdale, Riverdale, Landover, Cheverly, Oxon Hill, Fort Washington, Indian head, Morningside.