I-VU® UPC OPEN OPN-UPC PRODUCT INTEGRATED CONTROLLER
Factory-Installed Features
- Factory-installed option on rooftops, air-cooled chillers, and water-cooled chillers
- Pre-programmed to share equipment data with any BACnet Building Automation System – no on-site engineering required
- Supports Carrier communicating space sensors with field programming:
- Ideal for single zone rooftop applications
- Available in 4 flavors, 2 of which have large, easy-to-read LCD displays
- Feature a hidden communication port for network commissioning
- Supports plug-and-play connectivity to Carrier’s i-Vu Building Automation System:
- Integrated air source linkage algorithm
- Built-in user interface graphics, diagnostic trends and alarms
- Built-in demand limiting and inherent support for i-Vu Tenant Billing
Field-Installed Features
- Library of CCN to BACnet mapping templates available for common Carrier equipment, or create your own template using the Snap graphical programming tool
- Integrated air source linkage algorithm for plug-and-play connectivity to the i-Vu Building Automation System
- Supports demand limiting and i-Vu Tenant Billing
Communication Ports | BAS port (Port 1A): EIA-485 port for BACnet MS/TP communications, Modbus communications (future) or N2 communications (future). Baud rate is DIP switch selectable. LON-OC Port: For connecting a LON Option Card (future) Local Access Port: For system start-up and troubleshooting (115.2 kbps) Rnet Port: For connecting Carrier communicating space sensors |
Protection | Incoming power and network connections are protected by non-replaceable internal solidstate polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input, and output connections are also protected against voltage transient and surge events. |
Real Time Clock | Battery-backed real time clock |
Battery | 10-year Lithium CR2032 battery provides a minimum of 10,000 hours of trend data and time retention during power outages. |
Status Indicators | LED status indicators for power, network communication, run status and errors. |
Controller Addressing | Rotary DIP switches set BACnet MS/TP MAC address of controller |
Listed By | UL-916 (Canadian Std C22.2 No. 205-M1983), CE, FCC Part 15-Subpart B-Class A |
Environmental Operating Range | Operating: -22° to 150°F (-30° to 66°C), 10-95% relative humidity, non-condensing Storage: -24°F to 140°F (-30° to 60°C), 10-95% relative humidity, non-condensing |
Power Requirements | 24VAC +/- 10%, 50-60Hz 10VA power consumption 26VDC (25V min, 30V max) Single Class 2 source only, 100VA or less |
Dimensions | Length: 5-3/16” (13.2 cm) Width: 4-1/8” (10.5 cm) Depth: 2” (5.1 cm) Weight: 0.44 lbs. (0.20 kg) |
Integrated BACnet® Communications Card
Connecting your Carrier equipment to a BACnet MS/TP network has never been easier. Simply connect the UPC Open to the BACnet network, and your Carrier equipment is ready to integrate seamlessly into the i-Vu Building Automation System or any other BACnet Building Automation System.
Offering I-VU® UPC OPEN OPN-UPC PRODUCT INTEGRATED CONTROLLERS in:
VIRGINIA: Alexandria, Annandale, Arlington, Ashburn, Burke, Centreville, Chantilly, Crystal City, Dale City, Dulles, Fairfax, Falls Church, Fort Belvoir, Great Falls, Herndon, Leesburg, Lincoln, Lorton, Manassas, McLean, Oakton, Purcellville, Reston, Springfield, Stafford, Sterling, Vienna, Woodbridge.
MARYLAND: Annapolis, Aspen Hill, Beltsville, Bethesda, Chevy Chase, College Park, Gaithersburg, Hampstead, Hyattsville, Lanham, Laurel, Montgomery Village, Potomac, Rockville, Silver Spring, Takoma Park, Temple Hills, National Harbor, Cabin John, East Riverdale, Riverdale, Landover, Cheverly, Oxon Hill, Fort Washington, Indian head, Morningside.
WASHINGTON, DC
HVAC – Heating – Air Conditioning Repair Experts at Perryaire.